VERSION “K”: EXTENDED EMERGENCY PIN
VERSION “AK”: EXTENDED PIN AND AIR VALVES
INSTALLATION DIMENSIONS (mm)
HYDRAULIC FLUIDS PRESSURE COMPENSATOR MODULES.
VERSION “ZC”: ZINC PLATED VALVES
7
8
10
11 12
9
Solenoid valves according to “K” version have extended emergency actuator pins protruding from the solenoid
shape, that permit a quick and easy “Hand operation” of the valves, without the need of any tool. The actuator
pin and the end of the solenoid are protected by a flexible rubber cap that makes easy operation and protects
from moisture and water splashes.
Proportional valves according to “AK” version have extended emergency actuator pins that incorporate air
bleeding valves, to purge air from the solenoid tube for a simplified start-up of the system. The actuator pin
and the end of the solenoid are protected by a flexible rubber cap that makes easy operation and protects
from moisture and water splashes.
All valves HD3-* conform with ISO and CETOP specifications for
mounting surface dimensions (see also front page) and for valves
height. When assembled to its mounting plate valve HD3-* must
be fastened with 4 bolts M5 X 45 mm (or M5 x ** according to the
number of modules) tightened at 8 Nm torque. Of special interest is the
mounting of pressure compensator modules with HD3-P proportional
valves. Leakage between valve and mounting surface is prevented by
the positive compression on their seats of 4 seals of QUAD/O Ring type
9,25x1,68x1,68.
Seals and materials used on
standard valves HD3-* are
fully compatible with hydraulic
fluids of mineral oil base,
upgraded with antifoaming
and anti-oxidizing agents.
The hydraulic fluid must be
kept clean and filtered to ISO
4406 class 19/17/14, or better,
and used in a recommended
viscosity range from 10 cSt to
60 cSt.
Solenoid valves according to “ZC” version have central body zinc plated and protected against every type of corrosion due to saline ambiance or other
aggressive chemicals. Zinc thickness are on the valve body: 10-15 m; and 8/12 m on solenoids.
2-way pressure compensator for meter-in
application type AM3-PCP – see table AM-391.
When using the 2-way pressure compensators in
meter-in application, shown in the circuit diagram,
a constant pressure difference across the metering
edge of the proportional direction valve is held. In
this case, the pressure variations due to loading
changes, as well as pump pressure changes, are
compensated. That means that a pressure change
cannot result in flow increase. 3-way pressure
compensator type AM3-LS-P is able to operate
as “load sensing” device, by ischarging at T port,
at the same pressure of the user, the flow that
exceeds the flow rates required by the controlled
opening of the proportional 4-way valve.
12 37
N°4
5,3
10
8,5
150
88
45
49
56
0,75
12,5 40,5 15
73,5 68
52 21,5
73,5
32,5 6,25 6,25
45
12,7
21,5
30,2
5,1
15,5
25,9
31
215
N°4 OR 2037
P
T
A B
12 37
N°4
5,3
10
8,5
150
88
45
49
56
0,75
12,5 40,5 15
73,5 68
52 21,5
73,5
32,5 6,25 6,25
45
12,7
21,5
30,2
5,1
15,5
25,9
31
215
N°4 OR 2037
P
T
A B
V1-17 V1-17